Construction
Conductor Bare Cu 0,80mm
Dielectric FOAMED PE 3.65 ±0.10mm
First shield Al/PET+Al adhesive tape
Second shield Tinned Cu braid 50%
Sheath LSZH blue RAL5015 Diam 5.30±0.10mm
Printing ECS-COAX 75OHM HD LSZH CEI UNEL 36762 C-4 Uo=(400V) WW/YY 001m – Eca
Electrical properties
Conductor resistance <35 Ω/km at 20°C
Shield resistance  <29 Ω/km at 20°C
Standard impedance <75 ± 3Ω
Capacitance <53.0 ±3pF/m
VPP 84%
SRL dB 30-470 MHz>33

470-862 MHz>30

862-2150 MHz>26

2150-3000 MHz>22

Screen effect dB 30-1000 MHz>90

1000-2000 MHz>75

2000-3000 MHz>65

Min bending radius 5 x ext.diam
Signal trasmission CVBS: 800 mHD-SDI:160 m
Operating temperature -30°C +70°C
Frequency(MHz) Attenuation @20°C (dB/100m)
5 1.80
10 2.40
50 5.70
100 8.00
200 11.10
300 13.60
470 17.20
600 19.90
800 22.80
862 23.90
1000 26.20
1350 30.70
1500 32.90
1750  35.40
2150 39.80
2400 42.50
2750 45.80
3000 48.20
Smart code Item number Diameter mm. Weight Kg/Km
SC-53H STHF75D53HSABLM01 5.30±0.10 30.00
} The details expressed above have to be considered as an indication.
European Cable Service S.r.L. - Tel. +39 0583 436283 - www.europeancableservice.it - info@europeancableservice.it